Place of Origin: China Shandong
Brand Name: Shuangyi
Terms of Payment: L/C
The ventilator inductor is that provide one kind of new generation to ventilate the special purpose equipment system for the underground garage and large scale construction (for example supermarket, market, stadium, natatorium, book stacks, workshop, great hall, four seasons hall and so on) the blast, the platoon wind (concurrently discharges fume) .We recommends this equipment use with a garage discharge of wind (concurrently discharges fume) system to carry on the synthesis application, will become to be best effect, most economical suitable new generation ventilation system in the garage.
The new generation underground ventilation system, discharges fume the system with this installment union summary
The new generation ventilation system is by the air feeder, several blast inductors, the platoon wind smoke vent and the exhaust blower (concurrently discharges fume air blower) to be composed, is blows of an induction discharge of wind to discharge fume organically unifies.
The induction blast blower installment is the induction surrounding air, the transmission air replaces delivers the air flue, may prevent the both sides parking place the noxious gas detention. The use of discharges fume take usually removes 50% amount of wind, may improve the indoor air quality. This system facilitates are simplifies the design, make the garage artistic succinct easy to operate and save the overall investment,its the new generation integrated system which garage blast discharge of wind discharges fume unit, and fits fire protection standard is the new technical new equipment the present and a traditional discharge of wind and discharges fume system's organic combination and the application.
this equipment has three spraying supply-air outlets in the front: Middle for main efflux nozzle, uses blow out jet flow (amount of wind)to make the new atmosphere and the indoor air mixing to the direction advancement which assigns, replacing original delivers make the air flue transmission direction. And the other two efflux nozzles spout the jet flow (amount of wind), is impels the both sides to park automobile exhaust the dirty air dust and the stagnation in two on the other hand spandrel wall place not clean gas to the exhaust outlet direction, achieves promptly removes the nearby dirty gas goal.
Exhaust outlet is established in discharges fume the air flue smoke vent place of the garage, or established in the direct use smoke vent (often on status), its spacing does not surpass 30 meters to establish one, place of the main stream way, the both sides exhaust outlet altogether removes a garage discharge of amount of wind again about 50%.
The other 50% amount of wind should set up the exhaust outlet nearby the garage exhaust blower (to add motorized valve, when fire signal closure) place elimination. This discharge of wind, discharges fume system's air blower should for two speed, usually uses the low speed to remove 50% amount of wind, if on fire time, uses full speed removes 100% amount of wind. Its amount of wind is the garage volume 6 times/hour air change quantity.
Each smoke district should establish one system.
The character of blast inductor blower coordination discharge of wind discharges fume systems
1. Main jet big amount of wind, so to the transmission conduction current air volume, the firing distance is far.
2. Both sides inferior efflux nozzle forms is advantageous to the main jet advance angle, driving away automobile exhaust, the unclean gas dust advances to the exhaust outlet direction, is inhaled promptly (concurrently as fume flue).
3. Obviously enhanced in the garage the air quality, protecting entered the garage person's health.
4. usually uses fume flue discharge air, removes 50%amount of air, the air flue use the metal air flue, wind speed is 8-10m/s, the air flue sectional area is half of 100% amount of wind sectional area. When has fire, the discharging fume wind speed may increase (if use metal air flue, should not be faster than 20 m/s).It make the air discharge increase, reduced the air flue cross section ,and save the investment.
5. Discharges fume flue has not been faster than 20 m/s medium speed discharge of wind. Usually the discharge fume and air blower is in low speed, so it saves the electrical energy, also reduced the noise.
6. the discharge wind (concurrently discharges fume flue) cross section reduction, moreover the discharge wind and smoke vent is generally depending on the wall or the column, is the designing and the installment, making the garage to be artistic and has modern feeling.
Application
Underground parking garage
It can discharges the carbon monoxide and other noxious gases effectively, saves the space to facilitate pipeline's arrangement, the effect of ventilates the air is good. Comparing to the garage with the traditional ventilation system, the air quality is better.
The big building space
The big building space (for example stadium, indoor swimming pool, exhibition center, four seasons hall) may deliver upside hot air downward in winter, enhances the building first floor temperature, make the best of the heating source. It causes the air conditioning air current organization ideal through the induced flow, eliminates the dead angle, make the work area, the auditorium, the people active region maintains the comfortable temperature in summer
Garage, the warehouse, supermarket
Garage, the warehouse, supermarket
It may install the blast inductor blower on the channels upside, carrying on the air conditioning air current leading, enables the cold and hot air stream between equipment shelf flowing under the non-air flue's situation, does not form the dead angle.
|
|